Appendix 1. Firmware update
In order to update a firmware of RM-eye, you can connect between CN2 and PC using a serial
straight cable.
After confirmation that a power is shut down, you can slide pin1 and pin2 of SW5 to “ON”, and
turn on a power.
Please download a latest firmware from RM-eye support page, and update a firmware using
writing software. After writing a firmware, you can turn off a power and slide pin1 and pin2 of SW5
to “OFF”.
Please notice that parameters which you set is deleted if you update a firmware.
Figure 7. Firmware update
Pin Function RM-eye
1 NC -
2
RX
Connect to pin4 with 220 ohm
1
3 TX 2
4 Connect to pin2 with 220 ohm -
5 GND 3
6 NC -
7 Connect to pin8 -
8 Connect to pin7 -
9 NC -
You can use a serial straight cable which is a standard equipment of KHR-1, KHR-2HV,
KHR-1HV and Manoi.